Products
GE MAC1200ST ECG printer head |
|
Product name:GE MAC1200ST ECG printer head |
Item:GE MAC1200ST 心电图机热敏打印头 |
Price:GE MAC1200ST ECG printer head |
Details: |
GE MAC1200ST 心电图机热敏打印头
General Medical Devices, Inc., offers Resting ECG Solutions (GE MAC 1200 ST Resting ECG EKG Stress Testing System) with a complete package of algorithms and features like gender-specific 12SL, ACI TIPI, 15-lead, P-wave Signal Averaging, along with the latest technology for mobile data transfer to MUSE (MobileLink). As an authorized dealer of GE Healthcare’s comprehensive ECG/EKG product portfolio, we provide solutions for all care areas in the field of diagnostic cardiology and patient monitoring. Whether you are performing a resting, stress or Holter examination, or your cardiac patient needs full cardiac parameter monitoring or telemetry monitoring, General Medical Devices, Inc., offers a whole range of products that meet your different clinical needs.
GE MAC 1200 ST Resting Interpretive ECG Stress Testing System Comes complete with the following:
-
1 GE MAC1200-AAX-CXX-XXX EKG - ECG Machine - Brand New with full 3-year Factory Warranty
-
1 Pack Internal Battery Integrated Unit
-
1 Set Patient Cable
-
1 Set Lead wires
-
1 Set Silver Mactrode Electrodes
-
1 Operators Manual
-
1 Roll Premium Paper for GE MAC1200
-
1 1 Set Electrode Clips
-
1 ECG Professionals Maintenance/Inspection Tag
-
1 Pack Internal Memory Battery
-
FREE UPS Shipping
GE Healthcare MAC 1200 ST Resting/Stress ECG System: .
..
The MAC® 1200 ST digital, 12-lead electrocardiograph system offers comprehensive ECG solutions with practical features that meet the needs of hospitals, clinics, office-based practices and clinical trials. Its advanced algorithm capabilities, seamless connectivity to the MUSE® and CardioSoft Cardiology Information Systems and easy-to-use features provide the top level of quality and convenience users require.
• Operating Modes: - Automatic, 12lead simultaneous - Manual, real-time 6-channel - Arrhythmia, continuous monitoring with event documentation - Stress Test (optional) • One-touch operation for acquisition, analysis, storage and printing minimizes training. • Measurements, interpretation and memory are available in any combination to meet specific customer needs. • 4 user-definable fields for patient data entry flexibility. • Waveform display allows rapid assessment of ECG rhythm and signal quality. • Portable, lightweight design with carry handle allows the MAC 1200 ST to be easily taken wherever it’s needed. • Full-size paper accommodates multiple standard report formats. Optional archivist paper available for longer-term ECG storage. • Battery powered for added versatility. • KISS – electrode application system with device integrated suction pump (optional). • Stress test - 12-channel ST-measurements - variety of different stress test procedures and creation of individual parameters - automatic control of diverse bicycle ergometers and treadmills - advanced configuration possibilities of stage and final report Reliable decision support GE continues advancements in ECG acquisition and analysis, giving clinicians the diagnostic accuracy they have come to rely on. In fact, the accuracy of our Marquette® ECG analysis programs are continually validated against the clinical “gold standards” currently accepted by physicians. • Marquette 12-Lead ECG Analysis – Our Marquette® 12SLTM ECG analysis program provides true, computer- interpreted analysis of adult and pediatric populations. It is the most scientifically documented 12-lead ECG algorithm, and offers the greatest accuracy for a respectable second opinion. • Marquette 12SL with Gender Specific interpretation applies unique criteria for evaluating the ST segment, QT segment and T-wave of the ECG waveform, improving sensitivity to acute MIs in women and enhancing diagnostic confidence among even occasional ECG readers. • Auto-Arrhythmia Detection maximizes rhythm capabilities and minimizes paper consumption - and over-read time. Seamless connectivity Electronic information exchange to provide clinical data anytime, anywhere. • All digital, all the time – MAC 1200 ST’s digitally stored and formatted data protects against data loss that can occur in analog format. • Communication with MUSE/CardioSoft can help clinicians increase departmental productivity and reduce errors. MAC 1200 ST can instantly send and receive complete patient ECG data for immediate remote review or over read. • Cart-to-cart communication is also featured, making your ECG data even more accessible. Electrocardiograms can immediately be transmitted or received from another GE electrocardiograph, thus speeding up diagnosis and enhancing decision-making support. True cost of ownership Our MAC line of electrocardiographs are not only known for standing the test of time, but are designed with features to maximize departmental uptime, minimize patient rescheduling and lower replacement costs. • Modular lead wire assembly – Multi-Link Lead wires – Full variety of electrode adapters.
Physical specifications Height 3.7 in (94 mm) Width 14.5 in (370 mm) Depth 12.6 in (320 mm) Weight 12.3 lb (5.6 kg) with battery Performance specifications Power Supply Ratings 95 to 240 VAC Frequency 49 to 64 Hz Battery Type NiCad, 18V, 1.3 Ah Battery Charge Time 4 hours Processing Acquisition & Analysis 12 leads – simultaneously Signal Input Type CF according to IEC Digital Sampling 1000 samples/second/channel Dynamic Range – Differential signals for AC voltage ±10 mV – Superimposed DC voltage (Polarization voltage) ±600mV Resolution 5 μV Frequency Response 0.08 – 150 Hz Common Mode Rejection > 140dB Input Impedance > 100 MΩ Leakage Current < 10 μV Pacemaker Detection All leads, duration 0.1–2.5 ms, Sensitivity amplitude > 5 μV Operating Modes Automatic, 12lead simulation Manual, real-time 6-channel Arrhythmia, continuous monitoring with event documentation Stress Test (optional) Memory Resting: 40 ECG‘s Display Type LCD 320 x 240 pixel, backlit, Contrast adjustable Displayed Data Selected Lead Group, Operation Mode, Lead Check, Heart Rate, AC Filter, Muscle Filter, ADS, Gain, Speed, Name, ID, 3 ECG Waveforms Writer Type Thermal array print head Resolution Vertically 8 dots/mm, horizontally 25μm at 25 mm/s Paper type Z-fold Writer speed 5, 25, 50 mm/s Keyboard Type Membrane keypad with tactile feedback Environmental specifications Temperature (with battery) Transport: -30° to 60°C (-22° to 140°F) Operating: +10° to 40°C (50° to 104°F) Relative humidity Transport: 25-95% Operating: 25-95% Pressure Transport: 500 to 1060 hPa Operating: 700 to 1060 hPa Certification CE Marking • Compliance with: – CE Mark council directive, 93/42/ECC – Electromagnetic compatibility, EN 60601-1-2
Controls and Indicators: 227 492 04-C MAC® 1200 11 1 Power input 2 Paper door, windows allows you to check the paper supply 3 Patient cable connector 4 Serial interface (see chapter 13 "Technical Specifications") 5 Pow er switch (ON/STANDBY) 6 Keys to select a higher or lower HR alarm limit 7 Backspace key (to correct entered data) 8 Confirms entered data (Enter) 9 Displays the setup menu 10 Enables/disables the muscle filter (elimination of muscle artifact) 11 Selects the writer speed (25, 50, 5 mm/s) in 6 Lead Mode and the report formats in 12 Lead Mode 12 Selects the gain (5, 10, 20, 40 mm/mV) 13 Press to print the report or additional copies of the ECG, or to send/receive ECGs 14 Selects the ECG lead in 6 Lead Mode (in 12 Lead Mode, on the display only) 15 Sends ECG to memory/retrieves ECG from memory 16 Selects the 12 Lead Mode 17 Selects the 6 Lead Mode 18 Selects the Arrhythmia Mode 19 Starts/stops the selected operating mode, exits the setup menu and patient data entry 20 Indicators, green: selected mode started, amber: selected mode stopped 21 Enables entry of patient data 22 Indicator is illuminated when battery needs to be charged 23 Indicator is illuminated when unit is connected to the power line 24 Cursor control keys 25 Space bar 26 Shift key 27 Press to access special characters Explanation of symbols used on the device Consult accompanying documents Signal input Type CF signal input, highly insulated, defibrillation-proof Sly with IEC 60601/ EN 60601 requirements. It is Class I equipment and has a built-in rechargeable electrical power source. The device is suitable for intracardiac use. The device is suitable for continuous operation. - Choose a location which affords an unobstructed view of the monitor's screen and easy access to the operating controls. - The MAC 1200 has no additional protection against ingress of water. - Medical technical equipment such as the MAC 1200 must only be used by persons who have received adequate training in the use of such equipment and who are capable of applying it properly. - At the end of its service life; the MAC 1200 and its accessories must be disposed of in compliance with the special waste control regulations for electronic parts. If you have any questions in this matter, please contact Marquette Medical Systems. Literature Medical Device Directive 93/42/EEC EN 60601-1/1990 + A1: 1993 + A2: 1995: Medical electrical equipment. General requirements for safety EN 60601-1-1/9.1994 + A1 12.95: General requirements for safety. Requirements for the safety of medical electrical sys-tems. Requirements for the safety of medical electrical systems. EN 60601-2-25/1993: Medical electrical equipment. Part 2: Special requirements for the safety of electrocardiographs. IEC Publication 513/1994: Fundamental aspects of safety standards for medical equipment.
GE MAC 1200 ST Resting Interpretive ECG Stress Testing System Comes complete with the following:
-
1 GE MAC1200-AAX-CXX-XXX EKG - ECG Machine - Brand New with full 3-year Factory Warranty
-
1 Pack Internal Battery Integrated Unit
-
1 Set Patient Cable
-
1 Set Lead wires
-
1 Set Silver Mactrode Electrodes
-
1 Operators Manual
-
1 Roll Premium Paper for GE MAC1200
-
1 1 Set Electrode Clips
-
1 ECG Professionals Maintenance/Inspection Tag
-
1 Pack Internal Memory Battery
-
FREE UPS Shipping
|
|
[Next:热敏打印记录片/头可用于东江ECG-11D/邦健101/300等]→
|
|